| Model | STT-3KTL-MS | STT-3KTL-M | | STT-4KTL-M | STT-5KTL-M | STT-6KTL-M | |
| Input | | | | | | | | | |
| Max. Input Power (W) | | 4,800 | 4,800 | | 6,400 | | 8,000 | | 9,600 | |
| Start-up Voltage (V) | | 135 | 135 | | 135 | | 135 | | 135 | |
| Max. DC Input Voltage (V) | | 1100 | 1100 | | 1100 | | 1100 | | 1100 | |
| Rated DC Input Voltage (V) | | 620 | 620 | | 620 | | 620 | | 620 | |
| MPPT Voltage Range (V) | | 120-1000 | 120-1000 | | 120-1000 | | 120-1000 | | 120-1000 | |
| No. of MPP Trackers | | 1 | 2 | | 2 | | 2 | | 2 | |
| No. of DC Inputs per MPPT | | 1 | 1/1 | | 1/1 | | 1/1 | | 1/1 | |
| Max. Input Current (A) | | 15 | 2*15 | | 2*15 | | 2*15 | | 2*15 | |
| Output | | | | | | | | | |
| Rated Output Power (W) | | 3,000 | 3,000 | | 4,000 | | 5,000 | | 6,000 | |
| Max. Output Power (W) | | 3,300 | 3,300 | | 4,400 | | 5,500 | | 6,600 | |
| AC output rated apparent power(VA) | | 3,000 | 3,000 | | 4,000 | | 5,000 | | 6,000 | |
| Max. Apparent Power (VA) | | 3,300 | 3,300 | | 4,400 | | 5,500 | | 6,600 | |
| Rated Output Voltage (V) | | | | | 3 L/ N / PE,230 / 400V | | | | | |
| Rated AC Frequency (Hz) | | 50/60 | 50/60 | | 50/60 | | 50/60 | | 50/60 | |
| AC output rated current(A) | | 4.3 | 4.3 | | 5.8 | | 7.2 | | 8.7 | |
| Max. Output Current (A) | | 4.8 | 4.8 | | 6.4 | | 8.0 | | 9.6 | |
| Power Factor | | | | | 0.8 leading …0.8 lagging | | | | | |
| Max. total harmonic distortion | | | | <3% @Rated Output Power | | | | |
| DCI | | | | | <0.5%In | | | | |
| Efficiency | | | | | | | | | | |
| Max. Efficiency | | 98.1% | 98.1% | | 98.1% | | 98.1% | | 98.3% | |
| European Efficiency | | 97.9% | 97.9% | | 97.9% | | 97.9% | | 98.0% | |
| MPPT Efficiency | | 99.9% | 99.9% | | 99.9% | | 99.9% | | 99.9% | |
| Protection | | | | | | | | | |
| DC Reverse Polarity Protection | | | | | Integrated | | | | |
| Insulation Resistance Protection | | | | | Integrated | | | | |
| DC Switch | | | | | Integrated | | | | |
| Surge Protection | | | | | Integrated | | | | |
| Over-temperature Protection | | | | | Integrated | | | | |
| Residual Current Protection | | | | | Integrated | | | | |
| Islanding protection | | | | Frequency shift, Integrated | | | | |
| AC Short-circuit Protection | | | | | Integrated | | | | |
| AC Over-voltage Protection | | | | | Integrated | | | | |
| General Data | | | | | | | | | | |
| Dimensions (mm) | | | | | 410W*360H*120D | | | | |
| Weight (KG) | | | | 14 | | | | | |
| Protection Degree | | | | | IP66 | | | | |
| Self-consumption at Night (W) | | | | <1 | | | | | |
| Topology | | | | | Transformerless | | | | |
| Operating Temperature Range (° C) | | | | -30~60 | | | | | |
| Relative Humidity | | | | 0~100% | | | | | |
| Operating Altitude (m) | | | | 4000 (depreciativo@ > 3000) | | | | |
| Cooling | | | | | Natural Convection | | | | |
| Display | | | | | OLED & LED | | | | |
| Communication | | | | RS485/WiFi/ GPRS/LAN(Optional) | | | | |
| Compliance | | NB/T32004、IEC62109、IEC62116、VDE4105、VDE0126、UTE C15-712-1、AS4777、C10/11、 |
| | CEI0-21、RD1699、NBR16149、IEC61727、IEC60068、IEC61683、EN50549、EN61000 | | |