SUNWAYS STH 3~8KTL-HS
STORAGE SERIES
STH 3K/3.6KTL-HSS
STH 3K/3.6K/4.2K/4.6K/5K/6K/7K/8KTL-HS
MAX 97.6% EFFICIENCY
IP65 PROTECTION
Unbalance Output
Off-grid Backup
Battery Range 135~750V
Energy Management
Leading Features
- Max. efficiency up to 97.6%
- Fanless design, ultra-silence
- Intelligent power dispatching
- With AC output ranging from 3kW to 8kW
- Powerful load adaptability, support multiple loads stable access
- Oled display+App,two ways for data checking and management
- Uninterruptible power supply, switch to off-grid mode within 10ms
- 85~500V super wide battery voltage range, adapt to bigger capacity battery
Morning: low output, high demand
In the early morning, PV generation cannot meet the energy consumption, Sunways energy storage system will bridge the gap with the power stored in the battery in the previous day.
Midday: high output, low demand
PV generation is at its peak in the day time. But since nobody is at home and the energy consumption is very low, so most generated power will be stored in the battery of Sunways energy storage system.
Evening: high demand, zero output
The highest energy consumption in a day is at the evening and PV generates little even zero energy at this time. The Sunways energy storage system will bridge the gap with the power generated during the day.
TECHNICAL PARAMETERS
SINGLE PHASE:STR-3K/3.6K/4.2K/4.6K/5K/6K/7K/8KTL-HS
Model | STH-3KTL-HSS | STH-3.6KTL-HSS | STH-3KTL-HS | STH-3.6KTL-HS | STH-4.2KTL-HS | STH-4.6KTL-HS | STH-5KTL-HS | STH-6KTL-HS | STH-7KTL-HS | STH-8KTL-HS | |
PV Input | Max. Input Power (W) | 3,900 | 4,680 | 3,900 | 4,680 | 5,460 | 5,980 | 6,500 | 7,800 | 9,100 | 10,400 |
Start-up Voltage (V) | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | |
Max. DC Input Voltage (V) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | |
Rated DC Input Voltage (V) | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | 360 | |
MPPT Voltage Range (V) | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | 100-550 | |
No. of MPP Trackers | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
No. of PV Inputs per MPPT | 1 | 1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | 1/1 | |
Max. Input Current (A) | 15 | 15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | 15/15 | |
Max. Short-circuit Current (A) | 20 | 20 | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 | 20/20 | |
Battery | Battery Type | Lithium Battery (with BMS) | |||||||||
Battery Communication Mode | CAN / RS485 | ||||||||||
Battery Voltage Range (V) | 85-500 | ||||||||||
Max. Charge/Discharge Current (A) | 30/30 | ||||||||||
Rated Current of Built-in Fuse (A) | 63 | ||||||||||
Output | Rated Output Power (W) | 3,000 | 3,600 | 3,000 | 3,600 | 4,200 | 4,600 | 5,000/4,990 ① | 6,000 | 7,000 | 8,000 |
Max. Output Power (W) | 3,300 | 3,960 | 3,300 | 3,960 | 4,600 | 4,600 | 5,500/4,990 ① | 6,600 | 7,700 | 8,000 | |
Max. Apparent Power (VA) | 3,300 | 3,960 | 3,300 | 3,960 | 4,600 | 4,600 | 5,500/4,990 ① | 6,600 | 7,700 | 8,000 | |
Max. Input Apparent Power (VA) | 6,000 ② | 7,200 ② | 6,000 ② | 7,200 ② | 8,400 ② | 9,200 ② | 10,000 ② | 12,000 ② | 12,000 ② | 12,000 ② | |
Max. Charging Power of Battery (W) | 3,000 | 3,600 | 3,000 | 3,600 | 4,200 | 4,600 | 5,000/4,990 ① | 6,000 | 7,000 | 8,000 | |
Rated Output Voltage (V) | L/N/PE, 220/230/240V | ||||||||||
Rated AC Frequency (Hz) | 50/60 | ||||||||||
Max. Output Current (A) | 15 | 18 | 15 | 18 | 21 | 21 | 25/21.7 ① | 28.7 | 35 | 36.3 | |
Power Factor | 0.8 leading …0.8 lagging | ||||||||||
Max. Total Harmonic Distortion | <3% @Rated Output Power | ||||||||||
DCI | <0.5%In | ||||||||||
Output (Back-up) | UPS Switching Time | < 10ms | |||||||||
Max. Apparent Output Power (VA) | 3,300 | 3,960 | 3,300 | 3,960 | 4,600 | 4,600 | 5,500/4,990 ① | 8,800 | 11,000 | 13,200 | |
Peak Output Apparent Power (VA) | 3,900 ③ , 60s | 4,700 ③ , 60s | 3,900 ③ , 60s | 4,700 ③ , 60s | 5,500 ③ , 60s | 6,000 ③ , 60s | 6,500 ③ , 60s | 7,800 ③ , 60s | 9,100 ③ , 60s | 10,000 ③ , 60s | |
Voltage Harmonic Distortion | < 3% @Linear Load | ||||||||||
Efficiency | Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% |
European Efficiency | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | |
Max. Battery Charging Conversion Efficiency | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | |
Max. Battery Discharge Conversion Efficiency | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% | 96.6% |